Catalog String |
Description |
OCSUE |
A universal voltage (120V-277V) passive infrared sensor attached to a fixture used for detecting motion |
EM |
A universal voltage (120V-277V) battery backup attached to fixture that provides power for a period of time in case of building power loss. Wattage may vary according to product. |
EM10 |
A universal voltage (120V-277V) battery backup attached to fixture that provides power for a period of time in case of building power loss. The wattage on this unit is 10 watts. |
EM15 |
A universal voltage (120V-277V) battery backup attached to fixture that provides power for a period of time in case of building power loss. The wattage on this unit is 15 watts. |
EM20 |
A universal voltage (120V-277V) battery backup attached to fixture that provides power for a period of time in case of building power loss. The wattage on this unit is 20 watts. |
EMC |
EM with 6ft 16/4 non-dimming leads cord |
EMCD |
EM with 6ft 16/6 dimming leads cord |
EM20HV |
A high voltage (347V-480V) battery backup attached to fixture that provides power for a period of time in case of building power loss. The wattage on this unit is 20 watts. |
EXT |
36 inch extended wiring leads |
CLDS |
36 inch extended wiring leads from the center of the fixture |
CLDSP |
72 inch center wiring leads for pendant mount |
E6CN |
6ft cord 16/3 non-dimming; no plug installed on TOP END |
E6CD |
6ft cord 16/5 dimming; no plug installed on TOP END |
E10CN |
10ft cord 16/3 non-dimming; no plug installed on TOP END |
E10CD |
10ft cord 16/5 dimming; no plug installed on TOP END |
C6CN |
6ft cord 16/3 non-dimming; no plug installed on TOP CENTER |
C6CD |
6ft cord 16/5 dimming; no plug installed on TOP CENTER |
C10CN |
10ft cord 16/3 non-dimming; no plug installed on TOP CENTER |
C10CD |
10ft cord 16/5 dimming; no plug installed on TOP CENTER |
PM1LV |
9ft pre-wired plug assembly for row mounting (0-10V Dimming) |
PM2 |
9ft pre-wired plug assembly for row mounting (SD50 or EM10) |
PM2LV |
9ft pre-wired plug assembly for row mounting (SD50 or EM10 with 0-10V Dimming) |
SD50 |
Step Dimming driver to 50% |
515P |
5-15 plug only (120V) – straight blade |
L515P |
5-15P Twistlock Plug (125V) |
L615P |
6-15P Twistlock Plug (250V) |
L715P |
7-15P Twistlock Plug (277V) |
L820P |
8-20P Twistlock Plug (480V) |
L2420P |
24-20P Twistlock Plug only (347V) |
MHB PMK |
MHB Pendant Mount Kit |
KIT SHC |
Single Hub/Chain Mount Kit |
MCH10 |
Mini-hook 10ft Cable Kit (2 pk) |
MHB WG1 |
MHB 1 Wireguard |
MHB WG2 |
MHB 2 Wireguard |
MHB WG3 |
MHB 3 Wireguard |
ID |
Indirect Light (100% light up); a configuration of a fixture where it is inverted and all the light is directed upwards |
ALI PMK |
ALI Pendant Mount J-Box Kit |
SMK |
ALI Surface Mount Kit |
WG22 |
ALI Wire guard 2ft 2-row LED boards |
WG24 |
ALI Wire guard 2ft 4-row LED boards |
WG26 |
ALI Wire guard 2ft 6-row LED boards |
WG42 |
ALI Wire guard 4ft 2-row LED boards |
WG44 |
ALI Wire guard 4ft 4-row LED boards |
R16AC |
16″ Prismatic Acrylic Refractor for the RHB |
R16AW |
16″ White Acrylic Refractor for the RHB |
R16AD |
16″ Diffuse Acrylic Refractor for the RHB |
R16CPA |
16″ Acrylic Conical Drop Lens that attaches to any 16″ refractor |
R16FGC |
16″ Flat Glass Lens that attaches to any 16″ refractor |
R16WG |
16″ Wire guard that attaches to any 16″ refractor |
RHBPMK |
Pendant mount kit for the RHB |
RHB HOOK |
Hook for the RHB |
TBKT |
SDL T-Grid Collar (Qty 1) |
CHS36 |
Chain Hanger Set (36” length) (Qty 2) |
CHS60 |
Chain Hanger Set (60” length) (Qty 2) |
TCH10 |
10ft Toggle Cable Assembly 2pk |
PMK24 |
SDL 24” Pendant Kit (Qty 1) |
PMK36 |
SDL 36” Pendant Kit (Qty 1) |
PMK48 |
SDL 48” Pendant Kit (Qty 1) |
WG SDL/S |
SDL or S Wire guard 4ft |
AHB PMK1 |
AHB Single Pendant Mount Kit |
AHB PMK2 |
AHB Double Pendant Mount Kit |
AHB WG-18-24 |
AHB Wire guard (2pk) 18L/24L |
AHB WG-30 |
AHB Wire guard (2pk) 30L |
HC |
AUL Hook |
HCP120 |
AUL Hook, 3’ cord & 120V Twistlock Plug |
HCP208 |
AUL Hook, 3’ cord & 208V Twistlock Plug |
HCP240 |
AUL Hook, 3’ cord & 240V Twistlock Plug |
HCP277 |
AUL Hook, 3’ cord & 277V Twistlock Plug |
HCP480 |
AUL Hook, 3’ cord & 480V Twistlock Plug |
EXTD36 |
Dimming leads extended 36″ |
EXTD72 |
Dimming leads extended 72″ |
C3D |
3’ cord with dimming; no plug |
C3N |
3’ cord non-dimming; no plug |
C3DEM |
3’ cord with dimming and switch leg for battery |
E6CW |
EG3 Car Wash kit; 6’ black 16/3 SEOOW cord and fittings |
SL |
EG3 Stainless steel latches |
OMSWL |
Externally Mounted Wet Location Occupancy Sensor |
HUB |
Use with center mount applications (3/4” NPT HUB in BACK/TOP) |
BB |
Outdoor fixtures – Battery backup |
CWBB |
Outdoor fixtures – Cold weather battery backup |
SP1 |
10kV Surge protection |
SP |
6kV Surge protection |
OCSHV |
Occupancy Sensor, white housing 480V |
C3NED |
3’ cord non-dimming and switch leg for battery |
TNA |
OPS Pendant Mount 2″ Tenon adapter |
GRD HGR |
T-Grid Hanger Kit (Qty 2) |
PM1 |
9ft Pre-wired plug assembly for row mounting (Standard) |
FS |
Field Selectable. The color (CCT) and output (lumens) can be changed via one or more switches on the fixture. |
SM |
Surface mount accessory for drywall installation |
PFC22 |
2 ft Circular perf option used as a decorative element usually on troffers. |
PFR24 |
Rectangular perf option used as a decorative element usually on troffers. xx represents size such as 2ft or 4ft. |
FK22 |
2ft Flange kit for recessed mounting into drywall or sheet rock – wall or ceiling. |
FK24 |
4ft Flange kit for recessed mounting into drywall or sheet rock – wall or ceiling. |
IMBSBT1 |
|
IMSBT2 |
|
ALBC |
|
ALBCS1 |
|
ALBCS2 |
|
IMS1 |
|
IMS2 |
|
DIM |
|
IH |
Integral half louver provides shielding and backlight control with minimal impact on forward light distribution |
IL |
Integral full louver provides shielding and sharp backlight control with some impact on forward light distribution |
BB |
Battery backup integral to the fixture that provides power for a 90 minute period of time in case of power loss. Rated for temperatures down to 0°C. Wattage may vary by product. |
CWBB |
Battery backup integral to the fixture that provides power for a 90 minute period of time in case of power loss. Rated for temperatures down to -20°C. Wattage may vary by product. |
XPMA |
Pole mount adapter that allows for select wall packs to be pole mounted |
SP1 |
10kv Integral surge protection device that protects luminaire electrical components from damage during power surge events |
TB |
Terminal block allows for securing multiple wiring connections without the need for additional wire connectors. |
TP |
Tamper proof hardware features center pin torx screws that require a specialty screw driver to remove for increased vandal resistance |
EH |
Extended housing |
ALSC |
Wireless control module utilizes a 2.4 GHz self-healing mesh network allowing luminaries to communicate and be grouped/controlled together |
ALSCS |
Wireless control module with passive infrared occupancy sensor utilizes a 2.4 GHz self-healing mesh network allowing luminaries to communicate and be grouped/controlled together |
ALBCS |
Wireless control module with passive infrared occupancy sensor utilizes Bluetooth™ mesh network for outdoor and indoor lighting applications allowing luminaries to communicate and be grouped/controlled together |
EXT |
0-10v Dimming leads extended to housing exterior for use with controls provided by others |
DIM |
Indicates that the luminaires driver is capable of 0-10V dimming |
IMSBT |
Integral Bluetooth™ passive infrared occupancy and photocell sensor for dimming and on/off control of individual luminaires |
PCI |
Integral button photocell for on/off functionality depending on ambient lights levels (turns fixture off during the day) |
CR7P |
7 Pin control receptacle provides conduit for twist lock accessories such as photocells or wireless controllers. Shorting cap required for luminaire functionality if no photocell or wireless control is used. |
AMB |
Phosphor Converted Amber Colored Light |
2 |
Type 2 linear shaped pattern that is the ideal choice for wider walkways, entrance roadways, on-ramps, four-lane roadways or any area requiring long, narrow lighting |
3 |
Type 3 bat wing shaped pattern that provides a larger area of lighting coverage from a position along the perimeter of where lighting is required |
FT |
Forward Throw asymmetrical pattern that provides maximum forward throw from a position along the perimeter of where lighting is required |
5W |
Type 5 Wide symmetrical shaped pattern ideal for lighting the interior of parking areas and open spaces |
FTA |
Forward Throw Automotive linear shaped pattern that focuses a narrow band of light ideal for lighting the front row of automotive dealerships |
AM |
Automotive Merchandise asymmetrical pattern that provides a concentrated pattern of light ideal for perimeter and interior merchandise of automotive dealerships |
5Q |
Type 5 Square shaped pattern ideal for lighting the interior of parking areas, parking decks and open spaces |
5C |
Type 5 Concentrated symmetrical pattern ideal for parking garage entrances where high illumination levels are required |
5R |
Type 5 Rectangular shaped pattern ideal for lighting above the center lane of parking decks or along walkways requiring long, narrow lighting |
3W |
Type 3 Wide bat wing shaped pattern that provides a larger area of lighting coverage from a position along the perimeter of where lighting is required |
4F |
Type 4 Forward asymmetrical pattern that provides maximum forward throw from a position along the perimeter of where lighting is required |
5D |
Type 5 Diffuse symmetrical shaped pattern ideal for lighting the interior of parking areas, parking decks and open spaces while reducing glare and brightness |
AD |
Asymmetrical Diffuse pattern that provides forward throw from a position along the perimeter of where lighting is required while reducing glare and brightness |
FTW |
Forward Throw Wide asymmetrical pattern that provides maximum forward throw from a position along the perimeter of where lighting is required |
MT |
Medium Throw asymmetrical pattern that provides forward throw from a position along the perimeter of where lighting is required |
MTD |
Medium Throw Diffuse asymmetrical pattern that provides forward throw from a position along the perimeter of where lighting is required while reducing glare and brightness |